🔑Key Words First
| Word | Plain meaning |
|---|---|
| Electrocardiogram (ECG or EKG) | A recording of the heart's electrical activity picked up from the skin |
| Lead | One electrical 'viewpoint' on the heart |
| Depolarization / repolarization | Inside of a cell turning positive / returning to negative |
| Action potential | The brief electrical swing in a heart cell |
| SA node (sinoatrial node) | The heart's natural pacemaker in the right atrium |
| AV node (atrioventricular node) | The relay between atria and ventricles that delays the signal |
| Atria / ventricles | Upper / lower pumping chambers |
| P wave, QRS complex, T wave | ECG bumps for atrial depolarization, ventricular depolarization, ventricular repolarization |
| PR interval, QT interval, ST segment | Timing stretches between ECG landmarks |
| Millivolt (mV), millisecond (msec) | Units of voltage and time (one thousandth of a second) |
| Rhythm | Whether beats come at regular spacing |
| Bradycardia / tachycardia | Heart rate below 60 / above 100 beats per minute |
| Mean electrical axis (MEA) | The overall direction of the ventricles' electrical flow |
| Hypertrophy | Thickening of a muscle wall |
| Infarct / myocardial infarction (MI) | Heart muscle death from blocked blood supply |
| Ischemia | Muscle starved of blood but not yet dead |
| Angina | Chest pain from heart ischemia |
| Heart block | Signal delayed or stopped on its way from atria to ventricles |
| Mobitz type I (Wenckebach), Mobitz type II | Two kinds of second-degree heart block |
| Fibrillation / flutter | Disorganised electrical activity / fast but organised looping |
| Accessory pathway | An extra, abnormal electrical bridge |
| Reentrant tachycardia | Fast rhythm where the signal circles back in a loop |
| Hyperkalemia / hypokalemia | Too much / too little potassium in blood |
| Hypercalcemia / hypocalcemia | Too much / too little calcium in blood |
🔌What an ECG Shows
Where this fits
- Takes the cell-level action potentials and views them as one body-surface tracing
- Phases of the muscle-cell action potential map onto ECG parts
Phase 0→QRS complex
Phase 2→ST segment
Phase 3→T wave
Normal parts
| Part | Represents | Normal timing |
|---|---|---|
| P wave | Atrial depolarization | — |
| PR interval | P wave start to QRS start; mostly AV node delay | 120–200 msec |
| QRS complex | Ventricular depolarization | About 40–100 msec |
| ST segment | Ventricles fully depolarized (plateau) | Flat baseline |
| T wave | Ventricular repolarization | — |
| QT interval | QRS start to T wave end; ventricular action potential length | Shortens as heart rate rises |
| J point | End of QRS where ST begins | Baseline |
| R wave / S wave | First upward / first downward spike after R | — |
Wave height depends on
- Amount of muscle involved
- Speed of voltage change
- Angle between the lead and the current's direction
- Why QT shortens with fast rates: sympathetic drive shortens the action potential
- Why atrial repolarization is not seen: it is hidden within the QRS complex
Analogy: filming a runner
- The lead is a camera at a fixed spot
- Runner moving toward the camera gives a tall upward spike
- Runner moving across the view gives a small spike
- Runner moving away gives a downward spike
📏Graph Paper & Heart Rate
Where this fits
- Converts the waves above into numbers
| Axis | One big box | One small box | Scale |
|---|---|---|---|
| Time (horizontal) | 0.2 sec (200 msec) | 0.04 sec (40 msec) | 5 big boxes = 1 sec |
| Voltage (vertical) | 0.5 mV | 0.1 mV | — |
Rate shortcut: count big boxes between two R waves
| Big boxes | Rate (beats/min) |
|---|---|
| 1 | 300 |
| 2 | 150 |
| 3 | 100 |
| 4 | 75 |
| 5 | 60 |
| 6 | 50 |
- Between two numbers means a rate between them
- Alternative: count beats in 3 seconds and multiply by 20
- Normal range is 60–100 beats/min
- Rhythm is regular when R-to-R spacing stays the same
🧭Systematic ECG Reading
1 Rate and rhythm→2 Waves present?→3 PR interval→4 Axis
| Step | Question | Normal |
|---|---|---|
| 1 Rate | Between 60 and 100? | Yes |
| 1 Rhythm | Is R–R spacing even? | Yes |
| 2 Waves | P, QRS, T all visible and sensible? | Yes |
| 3 PR | 3–5 small boxes and consistent? | 120–200 msec |
| 4 Axis | Which quadrant? | −30° to +110° |
- Why a rhythm strip helps: it shows many beats in one line
🧲Mean Electrical Axis
Where this fits
- Step 4 of the reading routine
- Axis is the net direction of ventricular depolarization
- Quadrant method uses two leads, I and aVF
- Count net QRS deflection (up minus down)
- Positive means current flows toward that lead
| Lead I | aVF | Axis | Meaning |
|---|---|---|---|
| Positive | Positive | 0° to +90° | Normal |
| Positive | Negative | 0° to −90° | Left axis deviation (pathologic past −30°) |
| Negative | Positive | +90° to 180° | Right axis deviation |
| Negative | Negative | −90° to 180° | Extreme right (northwest) axis |
Left axis deviation causes
- Left ventricular hypertrophy
- Left anterior fascicular block
- Inferior MI
Right axis deviation causes
- Right ventricular hypertrophy
- Left posterior fascicular block
- Lateral MI
- Lung disease with high right-heart pressure
- Why axis shifts: the heart's electrical weight moves toward enlarged tissue and away from dead tissue
Analogy: compass
- The axis is the needle direction
- A bulky wall pulls the needle toward itself
- Dead tissue lets the needle swing away
🚧Heart Block
Where this fits
- The AV node is the usual choke point
- Links back to PR interval timing
| Type | PR interval | P to QRS link | Rhythm |
|---|---|---|---|
| First-degree | Over 200 msec, constant | Every P conducts | Regular, normal rate |
| Second-degree Mobitz I (Wenckebach) | Lengthens beat by beat, then a QRS drops | Cycle repeats | Irregular |
| Second-degree Mobitz II | Constant, then sudden dropped QRS | Fixed ratios such as 2:1, 3:2 | Regular or irregular |
| Third-degree (complete) | No consistent PR | P and QRS fully independent | Regular but slow ventricles |
- First-degree: slowed AV node conduction only
- Mobitz I: AV node tires progressively, then skips
- Mobitz II: all-or-none failure below the AV node; may progress to complete block
- Complete: no atrial signals reach ventricles
- Why the ventricles are slow: a backup pacemaker below the block takes over at its own low rate
- Atrial rate and ventricular rate differ
Trap
- Constant PR with dropped beats means Mobitz II, not Wenckebach
🌪️Atrial Rhythms & Pre-excitation
| Condition | Mechanism | ECG clues | Rhythm |
|---|---|---|---|
| Atrial flutter | Very fast, organised atrial looping (over 280/min) | Saw-tooth waves; no clear T | Typically steady |
| Atrial fibrillation | Chaotic, uncoordinated atrial activity | No P waves | Usually irregular |
| Wolff-Parkinson-White | Accessory pathway (bundle of Kent) bypasses AV node | Short PR; slurred R upstroke (delta wave); wide QRS | Steady, normal rate unless tachycardia |
- Flutter: atria still contract in coordinated fashion
- Fibrillation: no effective atrial contraction
- Why this matters: pooled atrial blood can clot, raising stroke risk
- WPW: signal skips the AV delay, giving a short PR
- WPW: impulse can circle back up the pathway, causing reentrant tachycardia
🧪Other ECG Changers
| Cause | ECG change |
|---|---|
| Transmural infarct, Prinzmetal angina (coronary spasm) | ST elevation |
| Subendocardial ischemia, stable exertional angina | ST depression |
| Hyperkalemia | Peaked T waves, shortened QT |
| Hypokalemia | U waves, prolonged QT |
| Hypercalcemia | Shorter QT |
| Hypocalcemia | Longer QT |
- Why hyperkalemia peaks the T: repolarization speeds up
- Why hypokalemia prolongs QT: repolarization slows
⚠️Exam Traps & Pearls
Traps
- Normal PR is 120–200 msec; first-degree block is over 200
- QRS timing and QT timing are different measures
- Rates counted between heavy lines are approximate
- Left axis deviation starts being pathologic beyond −30°
- ST elevation and depression point to different ischemia patterns
Pearls
- Short PR plus delta wave means WPW
- Saw-tooth means flutter; no P waves with irregular rhythm means fibrillation
- Calcium and potassium changes shift QT and T wave shape
✅Recap
Most important facts
- P is atria, QRS is ventricular depolarization, T is repolarization.
- PR is 120–200 msec and mostly AV delay.
- One big box is 0.2 sec; 300, 150, 100, 75, 60, 50 count method.
- Normal rate is 60–100 beats/min.
- Normal axis is about −30° to +110°.
- First-degree block has a long constant PR.
- Mobitz I lengthens then drops; Mobitz II drops suddenly.
- Complete block shows independent P waves and slow QRS.
- Flutter shows saw-teeth; fibrillation shows no P waves.
- WPW shows short PR and delta wave.
- ST elevation means transmural injury or spasm.
- Potassium and calcium alter QT and T wave shape.