🔑 Key Words First
| Word | Plain meaning |
|---|---|
| Cardiac output (CO) | Blood pumped out of the heart per minute |
| Venous return (VR) | Blood flowing back to the heart per minute |
| Stroke volume (SV) | Blood ejected per beat |
| Heart rate (HR) | Beats per minute |
| Preload | Stretch of the ventricle (heart pumping chamber) before it beats |
| Afterload | Load the ventricle pumps against; best marker is TPR |
| Total peripheral resistance (TPR) | Combined resistance of all body arterioles |
| Mean arterial pressure (MAP) | Average pressure in the arteries |
| Contractility | Squeezing strength of the heart at a given stretch |
| Frank-Starling mechanism | More filling leads to a stronger beat and more output |
| Right atrial pressure (RAP) | Pressure where blood re-enters the heart |
| Mean systemic filling pressure (Psf) | Pressure in the circulation when blood flow is stopped |
| Compliance | How easily a vessel stretches |
| Venoconstriction | Narrowing of veins |
| Muscle pump | Leg muscles squeezing veins to push blood upward |
| Systole / diastole | Heart squeezing phase / filling phase |
| Conduction velocity | Speed of the heart's electrical signal |
| Tachycardia / tachyarrhythmia | Fast heart rate / fast abnormal rhythm |
| Ventricular function curve | Graph: filling pressure versus output |
| Vascular function curve | Graph: right atrial pressure versus venous return |
| Sympathetic / parasympathetic nervous system (SNS / PNS) | 'Fight or flight' nerves / 'rest and digest' nerves |
| Cardiopulmonary receptors | Volume sensors in the heart and great veins |
| Baroreceptors | Pressure sensors in the aortic arch and carotid sinus |
| Supine | Lying flat |
| Dependent veins | Veins below heart level |
| Pooling | Blood collecting in stretchy veins |
| Subatmospheric | Pressure below the air pressure outside |
| Air embolism | Air entering a vein and traveling in blood |
| Trendelenburg position | Head-down tilt |
| Orthostatic intolerance | Failure to hold blood pressure when standing |
| Syncope | Fainting |
| Dysautonomia | Faulty automatic nerve control |
| Renin-angiotensin-aldosterone system (RAAS) | Hormone chain that raises blood volume |
| Venodilator / alpha blocker | Drug that widens veins / drug that blocks vessel-narrowing nerve signals |
🌍 Big Picture
- The heart and vessels form one closed loop.
- Flow out of the heart must equal flow back.
- So output depends on what returns.
- Where this fits: arterial pressure control feeds into how much blood the heart receives.
Vessels set venous return→Return sets preload→Preload and pump set output
↩️ Venous Return and Filling Pressure
- VR is flow, so it follows pressure ÷ resistance.
- Upstream pressure is Psf.
- Downstream pressure is RAP.
- Flow stops when RAP equals Psf.
VR = (Psf − RAP) ÷ resistance to return
Psf
- Typical value is about 7 mm Hg.
- It cannot be measured easily in patients.
- It depends on blood volume and venous compliance.
| Change | Psf | VR and CO |
|---|---|---|
| ↑ Blood volume (infusion, RAAS) | ↑ | ↑ |
| ↓ Blood volume (hemorrhage, vomiting, diarrhea, burns) | ↓ | ↓ |
| ↓ Venous compliance (sympathetic drive, muscle pump, exercise) | ↑ | ↑ |
| ↑ Venous compliance (sympathetic block, venodilators, alpha blockers) | ↓ | ↓ |
- Why less compliance helps: stiff veins squeeze blood toward the heart.
- Muscle pump also raises Psf.
Analogy: a squeezed water balloon
- More water raises the pressure inside.
- A stretchier balloon holds the same water at lower pressure.
⚙️ Four Determinants of Output
CO = HR × SV
| Determinant | Effect on CO |
|---|---|
| Heart rate | Depends on the cause |
| Contractility | Direct |
| Afterload (TPR) | Inverse |
| Preload (set by VR) | Direct (Frank-Starling) |
Exercise tachycardia: CO rises
- Faster rate shortens filling time.
- SNS raises contractility, shortening systole.
- That preserves diastolic filling time.
- SNS speeds electrical conduction.
- SNS narrows veins, keeping VR up.
- Muscle pump raises VR.
- So SV is maintained.
Tachyarrhythmia: CO falls
- Sudden fast rate cuts filling.
- SV and CO drop.
- SNS response comes too late.
- No muscle pump helps.
- So the compensations are missing.
Exam trap
- A higher heart rate does not always raise output.
- Cause of the rise decides the result.
📈 Cardiac Output and Venous Return Curves
| Curve | X-axis | Y-axis | Shape and meaning |
|---|---|---|---|
| Ventricular function | RAP (preload marker) | CO | Rises: more filling, more output |
| Vascular function | RAP | VR | Falls: higher RAP shrinks the pressure gradient; hits zero at Psf |
- Steady-state CO is where the two curves cross.
- Heart rate aside, CO changes only if a curve moves.
What moves the curves
| Change | Vascular curve | Ventricular curve | CO |
|---|---|---|---|
| Arteriolar dilation | Steeper; same Psf | Up and left (less afterload) | ↑ |
| Arteriolar constriction | Flatter; same Psf | Down and right (more afterload) | ↓ |
| ↑ Volume or ↓ venous compliance | Shifts right (↑ Psf) | — | ↑ |
| ↓ Volume or ↑ venous compliance | Shifts left (↓ Psf) | — | ↓ |
- Why dilation raises VR: lower resistance increases flow.
- Dilation helps both heart and vessels.
- Constriction hurts both heart and vessels.
Analogy: a shop's stock and sales
- Deliveries are venous return.
- Sales are cardiac output.
- Over time sales cannot exceed deliveries.
🪂 Gravity and Standing
- Below heart level, arterial and venous pressures rise by the same amount.
- About 80 mm Hg is added at the feet.
- The artery-to-vein gradient is unchanged.
- Veins are very compliant, so they pool blood.
- Pooled blood does not add to output.
- Gravity acts like a rise in venous compliance.
Stand up→Pooling in leg veins→VR ↓→SV ↓→MAP ↓
Cardiopulmonary receptors see low volume→SNS ↑, PNS ↓→Arterioles narrow, HR ↑, veins narrow
- Arterial baroreceptors join if MAP falls.
Above heart level
- Arterial pressure falls.
- Venous pressure turns negative.
- Surface veins collapse.
- Skull veins stay open, supported by tissue.
- A cut vein here can draw in air.
Clinical tips
- Central line: tilt head-down.
- Why: venous pressure becomes less negative.
- That lowers air embolism risk.
- Place the BP cuff at heart level.
- Cuff too high reads falsely low.
- Cuff too low reads falsely high.
Orthostatic intolerance
- MAP cannot be held when upright.
- Brain flow falls, causing dizziness or fainting.
- Common cause: low blood volume.
- Other causes: venodilators, heart failure, transplant, dysautonomia.
✅ Recap
Recap
- VR and CO are equal at steady state.
- VR = (Psf − RAP) ÷ resistance.
- Psf rises with volume and falls with compliance.
- Sympathetic drive and muscle pump raise VR.
- CO = HR × SV.
- Exercise keeps SV up despite a faster rate.
- Tachyarrhythmia drops CO.
- Contractility and preload raise CO; afterload lowers it.
- CO is set where the ventricular and vascular curves cross.
- Arteriolar dilation raises CO.
- Hemorrhage shifts the vascular curve left.
- Standing pools blood and lowers VR.
- Cardiopulmonary receptors start the standing reflex.
- Cuff above heart reads low.